@ -32,24 +32,21 @@ This jumper controls a 2:1 MUX switching the USB2.0 lanes of the Type-C port (J1
|
|||
* When the jumper is opened the Type-C port (J15) can be used to connect to the serial console of the Helios64.
|
||||
* When closed and system in recovery mode, the Type-C port (J15) can be used to flash directly the eMMC over USB.
|
||||
|
||||
## DC-IN Priority (P14 & P15)
|
||||
## DC-IN Priority (P15)
|
||||
|
||||
Helios64 supports 2x different DC-IN 12V inputs :
|
||||
|
||||
* AC Adapter (J16)
|
||||
* ATX PSU (J10)
|
||||
|
||||
You can plug both DC-IN inputs in order to have a failover setup that automatically switch to the other input if the first one fails. Jumpers P14 and P15 can be used to configure input priority.
|
||||
You can plug both DC-IN inputs in order to have a failover setup that automatically switches to the other input if the first one fails. Jumpers P15 can be used to force ATX as master DC-IN input.
|
||||
|
||||

|
||||
|
||||
| P15 | P14 | Description |
|
||||
|-----|-----|-------------|
|
||||
| Open | Open | O-Ring Connection |
|
||||
| Open | Close | Set ATX Priority |
|
||||
| Close | Open | Set AC Adapter Priority |
|
||||
| Close | Close | Self Locking Priority |
|
||||

|
||||
|
||||
| P15 | Description |
|
||||
|-----|-------------|
|
||||
| Open | O-Ring Connection |
|
||||
| Close | Set ATX Priority |
|
||||
|
||||
## SATA Controller Flash (P8)
|
||||
|
||||
|
|