## On-Board LEDs
|
||||
|
||||
| LED number | Color | Software control | Remarks |
|
||||
|------------|-------|------------------|---------|
|
||||
| LED1 | Green | Yes | Active-low |
|
||||
| LED2 | Red | Yes | Active-low |
|
||||
| LED3 | Green | Yes | Active-low |
|
||||
| LED4 | Green | Yes | Active-low |
|
||||
| LED5 | Green | Yes | Active-low |
|
||||
| LED6 | Green | Yes | Active-low |
|
||||
| LED7 | Green | Yes | Active-low |
|
||||
| LED8 | Green | No | Power indicator |
|
||||
|
||||
!!! info
|
||||
LED1 - LED7 is preconfigured for certain indicator under Linux, see [LED under Linux](#led-under-linux) section.
|
||||
|
||||
## Expansion Panel (J18)
|
||||
|
||||
Helios4 board was designed to either use the on-board LEDs or use a custom expansion panel (not-available).
|
||||
If you wish to use the header, insure to switch to OFF the Dip Switch SW2.
|
||||
|
||||

|
||||
|
||||
### Pinout Table
|
||||
|
||||

|
||||
|
||||
| Pin | LED number | Remarks |
|
||||
|-----|------------|---------|
|
||||
| 1 | - | 3.3V supply |
|
||||
| 2 | - | Not connected |
|
||||
| 3 | LED1 | Active-low |
|
||||
| 4 | LED2 | Active-low |
|
||||
| 5 | LED3 | Active-low |
|
||||
| 6 | LED4 | Active-low |
|
||||
| 7 | LED5 | Active-low |
|
||||
| 8 | LED6 | Active-low |
|
||||
| 9 | LED7 | Active-low |
|
||||
| 10 | - | GND |
|
||||
|
||||
!!! info
|
||||
LED1 - LED7 is preconfigured for certain indicator under Linux, see [LED under Linux](#led-under-linux) section.
|
||||
|
||||
### Wiring Diagram
|
||||
|
||||
Since the signals to control the LEDs are active low, connect the pin to LED's cathode.
|
||||
Below a wiring diagram example.
|
||||
|
||||

|
||||
|
||||
|
||||
## LED under Linux
|
||||
|
||||
| LED | Name | Default Trigger | Remarks |
|
||||
|------|----------------------|-----------------|---------|
|
||||
| LED1 | helios4:green:status | heartbeat | Blinking periodically |
|
||||
| LED2 | helios4:red:fault | none | See [Configuring Fault LED](#configuring-fault-led) |
|
||||
| LED3 | helios4:green:ata1 | ata1 | Blinking on SATA1 activity |
|
||||
| LED4 | helios4:green:ata2 | ata2 | Blinking on SATA2 activity |
|
||||
| LED5 | helios4:green:ata3 | ata3 | Blinking on SATA3 activity |
|
||||
| LED6 | helios4:green:ata4 | ata4 | Blinking on SATA4 activity |
|
||||
| LED7 | helios4:green:usb | usb-host | Blinking on USB activity, any port |
|
||||
|
||||
!!! note
|
||||
**ata** trigger requires additional patch to mainline kernel. The patch can be found [here](/helios4/files/led/libata_leds_trigger_mvebu.patch). **Armbian** builds are already patched, so no action is required.
|
||||
|
||||
The LEDs can be accessed under LEDs class in *sysfs*.
|
||||
|
||||
```
|
||||
root@helios4:~/# ls -l /sys/class/leds/
|
||||
|
||||
lrwxrwxrwx 1 root root 0 Dec 4 06:57 helios4:green:ata1 -> ../../devices/platform/io-leds/leds/helios4:green:ata1
|
||||
lrwxrwxrwx 1 root root 0 Dec 4 06:57 helios4:green:ata2 -> ../../devices/platform/io-leds/leds/helios4:green:ata2
|
||||
lrwxrwxrwx 1 root root 0 Dec 4 06:57 helios4:green:ata3 -> ../../devices/platform/io-leds/leds/helios4:green:ata3
|
||||
lrwxrwxrwx 1 root root 0 Dec 4 06:57 helios4:green:ata4 -> ../../devices/platform/io-leds/leds/helios4:green:ata4
|
||||
lrwxrwxrwx 1 root root 0 Dec 4 06:57 helios4:green:status -> ../../devices/platform/system-leds/leds/helios4:green:status
|
||||
lrwxrwxrwx 1 root root 0 Dec 4 06:57 helios4:green:usb -> ../../devices/platform/io-leds/leds/helios4:green:usb
|
||||
lrwxrwxrwx 1 root root 0 Dec 4 06:57 helios4:red:fault -> ../../devices/platform/system-leds/leds/helios4:red:fault
|
||||
|
||||
```
|
||||
|
||||
### LEDs Trigger
|
||||
|
||||
- none
|
||||
|
||||
No automatic trigger. Manually control the LED by manipulating "brightness".
|
||||
More info see [Configuring LED trigger](#configuring-led-trigger).
|
||||
|
||||
- heartbeat
|
||||
|
||||
LED "double" flashes at a load average based rate. The interval might change during heavy load.
|
||||
If the LED no longer blinks, it means the system is locked-up or hung and has to be reset.
|
||||
|
||||
- ata*N*
|
||||
|
||||
LED blinks on any read/write activity at specific SATA port.
|
||||
|
||||
- usb-host
|
||||
|
||||
LED blinks on USB activity at any port.
|
||||
|
||||
- panic
|
||||
|
||||
This trigger allows LEDs to be configured to blink on a kernel panic.
|
||||
|
||||
- timer
|
||||
|
||||
This allows LEDs to be controlled by a programmable timer via *sysfs*. delay_on to set how long
|
||||
the LED turned on and delay_off to set how long the LED turned off.
|
||||
|
||||
|
||||
### Configuring LED trigger
|
||||
|
||||
To configure, simply set the trigger type. For example to set Status LED triggered by timer
|
||||
|
||||
```
|
||||
echo timer | sudo tee -a /sys/class/leds/helios4\:green\:status/trigger
|
||||
```
|
||||
|
||||
Some of the triggers may expose additional parameters that can be configured further.
|
||||
|
||||
On **none** trigger, to turn ON the LED set the brightness bigger than 0.
|
||||
|
||||
```
|
||||
echo 1 | sudo tee -a /sys/class/leds/helios4\:green\:status/brightness
|
||||
```
|
||||
|
||||
and to turn OFF the LED set the brightness to 0.
|
||||
|
||||
```
|
||||
echo 0 | sudo tee -a /sys/class/leds/helios4\:green\:status/brightness
|
||||
```
|
||||
|
||||
On **timer** trigger, it will exposed *delay_on* and *delay_off* with default value of 0.5 seconds for both.
|
||||
To change the delay, set the respective parameter (value in milliseconds)
|
||||
|
||||
```
|
||||
echo 1000 | sudo tee -a /sys/class/leds/helios4\:green\:status/delay_on
|
||||
echo 200 | sudo tee -a /sys/class/leds/helios4\:green\:status/delay_off
|
||||
```
|
||||
|
||||
!!! note
|
||||
The changes is not retained across reboot. Use startup script or udev rules to make it permanent.
|
||||
|
||||
### Configuring Fault LED
|
||||
|
||||
While other LEDs are preconfigured, the fault LED remains unconfigured (trigger:**none**).
|
||||
|
||||
#### 1. As Kernel Panic Indicator
|
||||
|
||||
To configure the LED as Kernel panic indicator, set the trigger to **panic**. However this functionality might be redundant with Status LED, since if a kernel panic occurs and/or system hangs, the Status LED will no longer blink.
|
||||
|
||||
To trigger kernel panic to test the LED, run
|
||||
```
|
||||
echo c > /proc/sysrq-trigger
|
||||
```
|
||||
|
||||
!!! warning
|
||||
Triggering kernel panic can lead to data loss. Use with caution!
|
||||
|
||||
#### 2. As RAID Fault Indicator
|
||||
|
||||
To configure the LED as RAID fault indicator, please refer to [MDADM: Configure Fault LED](/helios4/mdadm/#configure-fault-led)
|
||||
|
||||